常州市医疗机构内镜清洗消毒质量调查 [中文引用][英文引用]

Survey on the Cleaning and Disinfection Quality of Endoscopes in Medical Institutions in Changzhou City

作者(英文):Lv Xufeng Zhang Jiantao Cao Gan Wang Peng 
单位: 
单位(英文): 
关键词(英文):Key words: endoscopes disinfection quality monitoring 
分类号:
出版年·卷·期(页码):2013·3·第2期(116-118)
DOI: 0
-----摘要:-------------------------------------------------------------------------------------------

摘要:目的 了解常州市医院内镜消毒现状,提高内镜消毒质量,为有效控制院内感染提供科学依据。方法 根据《内镜清洗消毒技术操作规范》(2004年版)和《消毒技术规范》(2002年版)要求, 对医院内镜及其相关用品的消毒质量进行调查。结果 37家不同级别医院共检测内镜及其相关用品527份,总合格率为74.9%,市级医院消毒质量结果好于县级医院,县级医院好于乡镇医院。内镜检测合格率为69.7%,清洗消毒槽内表面检测合格率为66.9%,消毒剂有效成分含量合格率为75.7%。结论 常州市内镜清洗消毒质量有待进一步提高,应加强内镜消毒质量管理,规范操作过程,加大内镜消毒工作的指导和监控力度。
 

-----英文摘要:---------------------------------------------------------------------------------------

Abstracts: Objectives To investigate the  status quo of endoscopes’ disinfection quality in hospitals of Changzhou, improve the quality of endoscope disinfection and provide scientific basis for effective control of nosocomial infection. Methods According to the requirement of Technical Operation Standard for Endoscopes Cleaning and Disinfection (2004) and Technical Standard for Disinfection (2002), a  survey on disfection quality of  endoscopes and related supplies in hospitals was carried out. Results Totally 527 samples of endoscopes and related supplies were collected from 37 hospitals with different levels . The qualified rate was 74.9%. The results of disinfection quality in municipal hospital were better than those of the county level, and the results of disinfection quality in hospitals at county level were better than those in township hospitals. The endoscopes’ testing qualified rate was 69.7%, the  qualified rate of surface on cleaning slots was 66.9%, and the qualified rate of active ingredient content for disinfectants was 75.7%. Conclusions The cleaning and disinfection quality in our city needs to be further enhanced. The endoscope sanitization quality management should be strengthened,The operation process should be standardized, and guidance and surveillance on the quality of endoscopes disinfection sould be facilitated.
 

-----参考文献:---------------------------------------------------------------------------------------

欢迎阅读《环境卫生学杂志》!您是该文第 1575 位读者!

若需在您的论文中引用此文,请按以下格式着录参考文献:
中文着录格式: 吕旭峰?,张建陶,曹淦,王鹂.常州市医疗机构内镜清洗消毒质量调查.环境卫生学杂志.2013;3(2):116-118.
英文着录格式: Lv,Xufeng,Zhang,Jiantao,Cao,Gan,Wang,Peng.Survey on the Cleaning and Disinfection Quality of Endoscopes in Medical Institutions in Changzhou City..2013;3(2):116-118.

与该文相关的文章(仅限于本刊内

已投本刊未发表相似文章

《环境卫生学杂志》编辑部 © 2014
  ICP备案号:京ICP备11024750号     京公安备案:11010202007828号